PK125 Pside-Kick: Typical Applications
The pside-kick® controls many different pumps set at various depths and pressures
Choose your GPM series pump and find the depth or distance from the surface to water information that applies. As long as the water level in your well is not less than the mininimum level and not more than the maximum level shown in the table, Pside-Kick® will work as designed.
Average Cycles Pump Cycles for Family of Four with No Irrigation
Cycle Stop Valve Pressure | NO CSV | CSV 50 PSI |
CSV 50 PSI |
CSV 50 PSI |
---|---|---|---|---|
Pressure Tank Size | 20 Gallon | 4.4 Gallon | 10 Gallon | 20 Gallon |
Average Daily Cycles | 35 | 31 | 25 | 18 |