PK125 Pside-Kick: VFD Controller Replacement

Instructions to Replace Franklin® Monodrive®

Replace Franklin Monodrive
Click image to view full size
  1. Replace Monodrive® controller with standard single Phase control box
  2. Remove micro switch and plug hole
  3. Install Pside-Kick® and wire power through pressure switch as per diagram

Instructions for Subdrive® 3 PH

If replacing microswitch when Subdrive® controller still works or when using other 3 phase converters:

Replace Grundfos Subdrive using 3 Phase Motors
Click image to view full size
  1. Install Pside-Kick® per instructions
  2. Remove micro switch and move wires to the provided 30/50 mechanical pressure switch only as per diagram
  3. Wire controllers independent 2 wire on/off control to pressure switch as per diagram

When Subdrive® controller fails:

  1. Install Pside-Kick® per instructions
  2. Replace three phase motor and Subdrive® controller with a standard single phase motor and control box
  3. Wire pressure switch as per diagram

Note: Verify existing pump wire size will work for single phase application.


Instructions to Replace Grundfos® CU301 Controller

Replace Grundfos CU301 Controller
Click image to view full size

Installation for SQE® controller replacement:

  1. Remove CU301 controller and transducer
  2. Install Pside-Kick®
  3. Wire pressure switch as per instructions