PK1A-LT: VFD Controller Replacement
Instructions for Monodrive®

- Replace Monodrive® controller with standard 1 Phase control box
- Remove micro switch and plug hole
- Install Pside-Kick® and wire power through pressure switch as per diagram
Instructions for Subdrive® using 3 Phase Motors
If replacing microswitch when Subdrive® controller still works or when using other 3 phase converters:

- Install Pside-Kick®
- Remove micro switch and move wires to the provided 40/60 pressure switch as per diagram
- Wire controllers independent 2 wire on/off control to pressure switch as per diagram
When Subdrive® controller fails:
- Install Pside-Kick® per instructions
- Replace three phase motor and Subdrive® controller with a standard single phase motor and control box
- Wire pressure switch as per diagram
Note: Verify existing pump wire size will work for 1 phase application.
Instructions to Replace Grundfos® CU301 Controller

- Remove CU301 controller and transducer
- Install Pside-Kick®
- Wire pressure switch as per instructions