CONSTANT PRESSURE EXPERTS FOR OVER 30 YEARS

PK1A Pside-Kick: Troubleshooting

Symptom Cause Remedy
Pump is cycling off and on Pressure switch or CSV1A valve not set correctly Cut off pressure must be higher than CSV1A pressure. Increase pressure switch cut off or decrease CSV1A valve setting.
Waterlogged pressure tank Replace pressure tank
Bad or torn diaphragm in CSV1A Replace diaphragm.
Manifold not assembled correctly Verify assembled as instructed
Low Pressure Demand is more than pump can provide at current pressure setting Reduce demand so it is within pump capabilities to maintain desired pressure.
CSV1A is not set correctly Reset CSV1A. (Turn adjust stem clockwise to increase psi and counter clockwise to decrease psi)
Chattering Too much air in tank Reduce air pressure in tank to 5-7 PSI below pressure switch cut in pressure.
CSV1A setting is too close to pressure switch cut off pressure Set pressure switch cut off pressure at least 10 PSI higher than CSV1A setting.
Pump rapid cycles at start up and then begins to function correctly Air pressure in tank too high Reduce air pressure in tank to 5-7 psi below cut in pressure.
Multiple check valves in system working against each other Remove all but the check valve or foot valve on the pump itself.
FREE US SHIPPING (except to AK and HI) *
We do ship into Canada via UPS International or USPS. Carrier is chosen depending on product ordered.
We ship to Alaska and Hawaii via USPS.
Customers may also choose DHL International on any product.
* Shipping charges will apply on international shipments and do not include any customs fees.

Copyright © 2024 Cycle Stop Valves, Inc.